1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(8): 775-783, 2023 Aug 20.
Artigo em Japonês | MEDLINE | ID: mdl-37344398

RESUMO

PURPOSE: We have been using a paper-based hard copy print (paper print) system of X-ray images, in which digital imaging and communications in medicine (DICOM) data can be directly output on papers from medical imaging systems or from a picture archiving and communication system (PACS) server, and they are utilized as patient referral materials or for preoperative planning. The purpose of this study was to compare the display performance of X-ray images on the printed paper and that on the liquid crystal display (LCD). METHODS: We measured contrast response to verify consistency of image appearance on both display systems. The contrast resolution was assessed by a CDRAD phantom. The spatial resolution was assessed by an X-ray test chart. RESULTS: The contrast response of the paper printer was not concordant with the grayscale standard display function (GSDF). The difference between the measured contrast response and the ideal GSDF on the paper was large in the high-density area. The low-contrast resolution on the paper was inferior to that on the LCD. The spatial resolving power on the paper was superior to that on the LCD. CONCLUSION: The display performance of the paper printer for X-ray images was clarified. X-ray images printed on the paper should be used carefully taking account of their characteristics of display performance.


Assuntos
Cristais Líquidos , Sistemas de Informação em Radiologia , Humanos , Raios X , Imagens de Fantasmas , Apresentação de Dados , Intensificação de Imagem Radiográfica
2.
Artigo em Japonês | MEDLINE | ID: mdl-33473075

RESUMO

PURPOSE: Digital breast tomosynthesis (DBT) imaging uses two types of image reconstruction. methods, i.e., filtered back projection (FBP) method and an iterative reconstruction (IR) method. Although the effect of the difference in the image reconstruction method on the image quality has been reported, these studies were performed using different apparatus or conditions. In this study, we examined the effect of image reconstruction on the image quality using the same equipment under the same conditions. METHOD: We measured reflection artifact, sharpness, signal detection ability, and granularity using DBT-photographed images by both the FBP and the IR methods. RESULT: Although the difference between the two methods was subtle for granularity, IR was found to be superior to FBP in all items tested. CONCLUSION: This study suggested the clinical usefulness of IR over FBP.


Assuntos
Algoritmos , Mamografia , Artefatos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(12): 1392-402, 2014 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-25672444

RESUMO

The International Commission on Radiological Protection recommends diagnostic reference levels (DRL) in each radiological examination for justification and optimization of patients' dose in medicine. The aim of our study was to propose the dose management system by utilizing dose information in diagnostic X-ray radiation dose structured report (Dose SR) in The Digital Imaging and Communications in Medicine to optimize radiation dose in institutions. Our dose management system is able to organize dose information obtained from various angiography systems and CTs. It is possible to provide this information to operators for justification and optimization of patient dose. Our system would be useful for the estimation of organ dose and could be used for the determination of local DRL (LDRL) for each radiological practice. In addition, the optimization became possible to compare LDRL with national DRL.


Assuntos
Angiografia/normas , Sistemas de Gerenciamento de Base de Dados , Doses de Radiação , Proteção Radiológica/normas , Sistemas de Informação em Radiologia , Bases de Dados Factuais , Humanos , Padrões de Referência
4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 65(6): 773-81, 2009 Jun 20.
Artigo em Japonês | MEDLINE | ID: mdl-19602802

RESUMO

Optical density of the lung area in pediatric digital chest radiography using an indirect flat panel detector (FPD) system were changed enormously by the influence of such factors as the size of lung area, gas of retroperitoneum, and so on. Our purpose in this study was to improve the stability of lung density on output images by means of optimizing histogram analysis. Chest images of a lung phantom were taken at various X-ray tube voltages and processed using a half-type region of interest (ROI) for the lung area. The shape of the histogram obtained by two different calculation methods including frequency distribution and cumulative relative frequency were compared, and digital chest images of 110 clinical cases in our hospital were classified into three age-groups (under 6 years old, over 6 years old and under 13 years old, and over 13 years old) and their histograms were analyzed. In conclusion, it was important that to analyze the histograms of age-groups, a cumulative relative frequency histogram should be used because the influence of X-ray tube voltage was lower than the frequency distribution histogram, and stabilized lung density under 6 years old could be obtained if the value of the imaging parameter for lung density from default was 90% to 85% or 80% because the distribution of lung area and its center value were significantly lower than in those over 13 years old.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Adolescente , Fatores Etários , Criança , Humanos , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/instrumentação , Radiografia Torácica/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...